(A) Box: PG3048BA18 Cover: PG3048HA0017 Precast polymer concrete enclosures are for use as
PG1730BA12 PG3048HA0012 a splice box, pull box, equipment enclosure or any
application requiring easy access to an under-
ground service. They are stackable for increased
depth, with straight sides for easy adjustment of
box to grade.
Catalog # Description
STRONGWELL/QUAZITE PR STYLE BOX
•Extremely strong, lightweight, easy to install, nonconductive, corrosion/impact/UV
resistant, stable under freeze/thaw conditions
•Available in the following sizes: 27” diameter x 36” deep, with design load at
15,000 lbs. and test load at 22,568 lbs.; 39” diameter x 18”, 24”, 36” and 48” depths,
with design load at 22,568 lbs. and test load at 33,852 lbs.
•Standard (CA) and heavy-duty (HA) covers are available for all sizes. Standard and
custom cover logos are available.
•CA covers have design load at 8,000 lbs. and test load at 12,000 lbs.; HA covers have
design load at 15,000 lbs. and test load at 22,568 lbs.
(B) Box: PR2732BA36 Cover: PR2700CA17 Round precast polymer concrete enclosures,
LR3944BA24 PR3900HA12 with cover that cannot fall into the box
Catalog # Description
STRONGWELL/QUAZITE CELL SITE BOX
•Extremely strong, lightweight, easy to install, nonconductive, corrosion/impact/UV
resistant, stable under freeze/thaw conditions
•Removable split cover allows easy access to cable lines.
•Sixteen 4” terminals and open area inside box provide room to install multiple lines.
•Equipment changes and upgrades are easy and cost effective.
•Size: 48” x 48” x 36”
(C) PG4848Z51109 and PG4848Z51509 Precast polymer concrete assembly, with 16
terminators and replaceable cover, intended for
use at cell sites
Catalog # Description
Equipment Pads
STRONGWELL/QUAZITEELECTRICAL/TELEPHONE EQUIPMENT PADS
•Extremely strong, lightweight, easy to install, nonconductive, corrosion/impact/UV
resistant, stable under freeze/thaw conditions
•Pads will support weight of equipment mounted to them without bending or
cracking.
•Electrical pads and box pads work with most transformers and switchgear
manufactured today.
•Telephone equipment pads accommodate most telephone cabinets manufactured.
•Throat sizes and insert locations can be designed to meet your requirements.
•Optional SPLITT-PAD
®
design makes retrofit installations easy and eliminates the need
to disconnect service during installation.
•Sizes range from 22”x36” to 117”x 75”
(D) PH42421225S3T Precast polymer concrete pads reinforced with a
PL72601032A4T heavy-weave fiberglass, for use as a replacement
PK72640935B4T for concrete and fiberglass pads
PB2436BA18
Catalog # Description
Enclosures
STRONGWELL/QUAZITE
®
PG STYLE BOX
•Extremely strong, lightweight, easy to install, nonconductive, corrosion/impact/UV
resistant, stable under freeze/thaw conditions
•UL Listing, which is available for enclosures sized through 30” x 48”, ensures the end
user that the product will perform as expected in the intended application.
•Available in the following sizes, with 12” to 48” depths (sizes in bold are UL Listed):
11“ x 18“, 13“ x 24“, 17“ x 30“, 24” x 24”, 24“ x 36“, 30“ x 48“, 30” x 60”, 36” x 36”,
36” x 60”, 36” x 72”, 48” x 48”, 48” x 72”, 48” x 96”
•Design load at 22,568 lbs. and test load at 33,852 lbs.
•CA, HA and HH covers are available for all sizes (HH cover not available for 24” x 24”).
Standard and custom cover logos are available.
•CA covers have design load at 8,000 lbs. and test load at 12,000 lbs.; HA covers have
design load at 15,000 lbs. and test load at 22,568 lbs.; HH covers have design load at
22,568 lbs. and test load at 33,852 lbs.