ADC H2TU-C-388 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro ne ADC H2TU-C-388. ADC H2TU-C-388 User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 66
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
HiGain
HiGain
USER MANUAL
MODE SEL
SETUP
STATUS
RS
DCE
232
HiGain
HDSL2
H
2
T
U
3
8
8
1
L
H2TU-C-388 List 1 Line Unit
Part Number: 150-2406-01
CLEI: VACHKW0C
Zobrazit stránku 0
1 2 3 4 5 6 ... 65 66

Shrnutí obsahu

Strany 1 - USER MANUAL

HiGainHiGainUSER MANUALMODE SELSETUPSTATUSRSDCE232HiGainHDSL2H2TU•3881LH2TU-C-388 List 1 Line UnitPart Number: 150-2406-01CLEI: VACHKW0C

Strany 2 - 152-388-100-02, Issue 2

Overview 152-388-100-02, Issue 22 June 6, 2000 H2TU-C-388 List 1COMPATIBILITYThe H2TU-C-388 List 1 is designed to mount in DDM+ high-density shelv

Strany 3 - INSPECTING SHIPMENT

152-388-100-02, Issue 2 Front PanelH2TU-C-388 List 1 June 6, 2000 3FRONT PANELFigure 1 shows the H2TU-C-388 List 1 front panel. Table 1 on page 4 d

Strany 4

Front Panel 152-388-100-02, Issue 24 June 6, 2000 H2TU-C-388 List 1Table 1. Front-Panel DescriptionFront-Panel Feature FunctionFront-panel display

Strany 5 - TABLE OF CONTENTS

152-388-100-02, Issue 2 Front PanelH2TU-C-388 List 1 June 6, 2000 5Table 2 lists the front-panel display messages. The four-character display repor

Strany 6

Front Panel 152-388-100-02, Issue 26 June 6, 2000 H2TU-C-388 List 1SMJK Remote SmartJack Loopback DSX-1 signal is looped back to the network at th

Strany 7 - LIST OF FIGURES

152-388-100-02, Issue 2 InstallationH2TU-C-388 List 1 June 6, 2000 7INSTALLATIONFigure 2. Installing the H2TU-C-388 into a Shelf1 Align the H2TU-C-

Strany 8 - LIST OF TABLES

Installation 152-388-100-02, Issue 28 June 6, 2000 H2TU-C-388 List 1VERIFICATIONOnce the H2TU-C-388 List 1 is installed, verify that it is operati

Strany 9 - OVERVIEW

152-388-100-02, Issue 2 ProvisioningH2TU-C-388 List 1 June 6, 2000 9PROVISIONINGThere are two provisioning methods: • Use the MODE and SEL buttons

Strany 10 - APPLICATIONS

Provisioning 152-388-100-02, Issue 210 June 6, 2000 H2TU-C-388 List 1Resetting to Factory Default ValuesAll user options for the H2TU-C-388 List 1

Strany 11 - FRONT PANEL

152-388-100-02, Issue 2 ProvisioningH2TU-C-388 List 1 June 6, 2000 115 Configure the maintenance terminal to the following communication settings:•

Strany 12

152-388-100-02, Issue 2ii June 6, 2000 H2TU-C-388 List 1Revision History of This ManualCopyrightJaunary 18, 2002© 2002 ADC DSL Systems, Inc. All r

Strany 13

Provisioning 152-388-100-02, Issue 212 June 6, 2000 H2TU-C-388 List 1Figure 3. Logon ScreenTable 4. Logon Screen MenusPress this key: To access th

Strany 14

152-388-100-02, Issue 2 ProvisioningH2TU-C-388 List 1 June 6, 2000 13PROVISIONING TASKSAfter the HiGain Line Unit is successfully installed, perfor

Strany 15 - INSTALLATION

Provisioning 152-388-100-02, Issue 214 June 6, 2000 H2TU-C-388 List 1Setting Circuit ID NumbersThe Inventory screen provides product information o

Strany 16 - VERIFICATION

152-388-100-02, Issue 2 ProvisioningH2TU-C-388 List 1 June 6, 2000 15Configuring the SystemThe Config menu (Figure 6) allows you to make the follow

Strany 17 - PROVISIONING

Provisioning 152-388-100-02, Issue 216 June 6, 2000 H2TU-C-388 List 1Figure 7. Configuration Menu - Standard Options (Defaults Shown)Figure 8. Con

Strany 18 - USING A MAINTENANCE TERMINAL

152-388-100-02, Issue 2 ProvisioningH2TU-C-388 List 1 June 6, 2000 17Table 5 describes the Standard Config screen options and lists their front-pan

Strany 19 - The Logon Screen

Provisioning 152-388-100-02, Issue 218 June 6, 2000 H2TU-C-388 List 1H2TU-R TLOS Loopback TLOS ENA Enables a logic loopback at the H2TU-R when an

Strany 20 - Table 4. Logon Screen Menus

152-388-100-02, Issue 2 ProvisioningH2TU-C-388 List 1 June 6, 2000 19HDSL2 BER Threshold (HBER) Option. The HBER option permits monitoring of loop

Strany 21 - PROVISIONING TASKS

Provisioning 152-388-100-02, Issue 220 June 6, 2000 H2TU-C-388 List 1DS1 BER (DBER) Option. The DS1 BER alarm occurs when any of the DS1 or DSX-1

Strany 22 - Setting Circuit ID Numbers

152-388-100-02, Issue 2 ProvisioningH2TU-C-388 List 1 June 6, 2000 21Clearing the History, Alarm, and Event Log ScreensClear the History, Alarm and

Strany 23 - Configuring the System

152-388-100-02, Issue 2 Using This ManualH2TU-C-388 List 1 June 6, 2000 iiiUSING THIS MANUALThe following conventions are used in this manual:• Mon

Strany 24

Monitoring System Activity and Performance 152-388-100-02, Issue 222 June 6, 2000 H2TU-C-388 List 1MONITORING SYSTEM ACTIVITY AND PERFORMANCEThe H

Strany 25

152-388-100-02, Issue 2 Monitoring System Activity and PerformanceH2TU-C-388 List 1 June 6, 2000 233 To initiate a loopdown of all active loopbacks

Strany 26

Monitoring System Activity and Performance 152-388-100-02, Issue 224 June 6, 2000 H2TU-C-388 List 1USING THE PERFORMANCE SCREENS TO VIEW PERFORMAN

Strany 27

152-388-100-02, Issue 2 Monitoring System Activity and PerformanceH2TU-C-388 List 1 June 6, 2000 25Figure 13. H2TU-R DS1 48-Hour Performance Histor

Strany 28 - Resetting the H2TU-C

Monitoring System Activity and Performance 152-388-100-02, Issue 226 June 6, 2000 H2TU-C-388 List 1Examples of current statistics screens are show

Strany 29

152-388-100-02, Issue 2 Monitoring System Activity and PerformanceH2TU-C-388 List 1 June 6, 2000 27Table 9. Acronyms Used on the DS1 Performance Hi

Strany 30 - PERFORMANCE

Monitoring System Activity and Performance 152-388-100-02, Issue 228 June 6, 2000 H2TU-C-388 List 1Performance History at the HDSL2 InterfaceThe H

Strany 31 - SPACEBAR ENTER

152-388-100-02, Issue 2 Monitoring System Activity and PerformanceH2TU-C-388 List 1 June 6, 2000 29Figure 19. H2TU-C HDSL2 25-Hour Performance Hist

Strany 32 - SPACEBAR

Monitoring System Activity and Performance 152-388-100-02, Issue 230 June 6, 2000 H2TU-C-388 List 1USING THE PERFORMANCE SCREENS TO VIEW ALARM DAT

Strany 33

152-388-100-02, Issue 2 Monitoring System Activity and PerformanceH2TU-C-388 List 1 June 6, 2000 31Alarm History at the DS1 InterfaceThe Alarm Hist

Strany 34

Inspecting Shipment 152-388-100-02, Issue 2iv June 6, 2000 H2TU-C-388 List 1

Strany 35

Monitoring System Activity and Performance 152-388-100-02, Issue 232 June 6, 2000 H2TU-C-388 List 1Table 11. DS1 Alarm DescriptionsScreen Alarm Fr

Strany 36

152-388-100-02, Issue 2 Monitoring System Activity and PerformanceH2TU-C-388 List 1 June 6, 2000 33Alarm History at the HDSL2 InterfaceFigure 23 sh

Strany 37

Monitoring System Activity and Performance 152-388-100-02, Issue 234 June 6, 2000 H2TU-C-388 List 1USING THE EVENT LOG TO TRACK SYSTEM EVENTSTo vi

Strany 38

152-388-100-02, Issue 2 Monitoring System Activity and PerformanceH2TU-C-388 List 1 June 6, 2000 35Table 13. Event Log Entry Messages ListEvent Log

Strany 39

Testing 152-388-100-02, Issue 236 June 6, 2000 H2TU-C-388 List 1TESTINGThis section provides information about front-panel system alarms, LOS and

Strany 40

152-388-100-02, Issue 2 TestingH2TU-C-388 List 1 June 6, 2000 37Alarm Option for DLC FeedTo improve HiGain compatibility with the switch-to-protect

Strany 41

Testing 152-388-100-02, Issue 238 June 6, 2000 H2TU-C-388 List 1Remote LOS and AIS ResponseFigure 25 shows the different ways the H2TU-R can respo

Strany 42

152-388-100-02, Issue 2 TestingH2TU-C-388 List 1 June 6, 2000 39LOOPBACK OPERATIONHiGain has a family of loopback options for analyzing circuit fun

Strany 43

Testing 152-388-100-02, Issue 240 June 6, 2000 H2TU-C-388 List 1Table 15. Summary of HiGain Loopback Codes and Activation MethodsMethod of Activat

Strany 44 - FRONT-PANEL SYSTEM ALARMS

152-388-100-02, Issue 2 TestingH2TU-C-388 List 1 June 6, 2000 41Special Loopback CommandsIn addition to the GNLB loopback command mode, a HiGain sy

Strany 45 - Retiring System Alarms

152-388-100-02, Issue 2 Table of ContentsH2TU-C-388 List 1 June 6, 2000 vTABLE OF CONTENTSOverview ________________________________________________

Strany 46 - Remote LOS and AIS Response

Testing 152-388-100-02, Issue 242 June 6, 2000 H2TU-C-388 List 1Manual Loopback SessionA manual loopback session allows you to select any one of t

Strany 47 - Premises

152-388-100-02, Issue 2 TestingH2TU-C-388 List 1 June 6, 2000 434 Press SEL to activate the selected loopback. The previous loopback is terminated.

Strany 48

Testing 152-388-100-02, Issue 244 June 6, 2000 H2TU-C-388 List 14 Have the CO tester send the NLOC (4-in-7) inband loopup for 5 seconds. You shoul

Strany 49 - Special Loopback Commands

152-388-100-02, Issue 2 TestingH2TU-C-388 List 1 June 6, 2000 45A1LB, A2LB, and A5LB Test ProceduresUsing the codes listed in Table 16, a network t

Strany 50 - Manual Loopback Session

Testing 152-388-100-02, Issue 246 June 6, 2000 H2TU-C-388 List 14 Once armed, the H2TU-C-388 can be looped back by sending Intelligent Office Repe

Strany 51 - LOOPBACK TEST PROCEDURES

152-388-100-02, Issue 2 TestingH2TU-C-388 List 1 June 6, 2000 47A3LB and A4LB Test ProceduresThe H2TU-C-388 can be looped back by sending the Addre

Strany 52

Appendix A - Specifications 152-388-100-02, Issue 248 June 6, 2000 H2TU-C-388 List 1APPENDIX A - SPECIFICATIONSPowerLine Voltage 0, -185 VdcCO Sup

Strany 53

152-388-100-02, Issue 2 Appendix A - SpecificationsH2TU-C-388 List 1 June 6, 2000 49POWER CONSUMPTIONThe maximum power consumption and heat dissipa

Strany 54

Appendix A - Specifications 152-388-100-02, Issue 250 June 6, 2000 H2TU-C-388 List 1LOOP ATTENUATIONEach loop has no more than 35 dB of loss at 19

Strany 55 - A3LB and A4LB Test Procedures

152-388-100-02, Issue 2 Appendix A - SpecificationsH2TU-C-388 List 1 June 6, 2000 51Fuse AlarmPin 117 on the card-edge connector is a fuse alarm th

Strany 56 - APPENDIX A - SPECIFICATIONS

Table of Contents 152-388-100-02, Issue 2vi June 6, 2000 H2TU-C-388 List 1Testing ________________________________________________________________

Strany 57 - MAXIMUM CURRENT DRAIN

Appendix B - Functional Operation 152-388-100-02, Issue 252 June 6, 2000 H2TU-C-388 List 1APPENDIX B - FUNCTIONAL OPERATIONADC HDSL2 technology pr

Strany 58 - Ω per kft

152-388-100-02, Issue 2 Appendix C - CompatibilityH2TU-C-388 List 1 June 6, 2000 53APPENDIX C - COMPATIBILITYThe HiGain system uses HDSL2 transmiss

Strany 59 - CRAFT PORT

Appendix D - Product Support 152-388-100-02, Issue 254 June 6, 2000 H2TU-C-388 List 1APPENDIX D - PRODUCT SUPPORTADC Customer Service Group provid

Strany 60 - ROUND FAULT DETECT

152-388-100-02, Issue 2 Appendix E - AbbreviationsH2TU-C-388 List 1 June 6, 2000 55APPENDIX E - ABBREVIATIONSAACO: Alarm Cutoff AIS: Alarm Indica

Strany 61 - APPENDIX C - COMPATIBILITY

Appendix E - Abbreviations 152-388-100-02, Issue 256 June 6, 2000 H2TU-C-388 List 1SES-P: Severely Errored Seconds - Path SF: SuperFrame SMJK: S

Strany 62 - APPENDIX D - PRODUCT SUPPORT

CERTIFICATION AND WARRANTYFCC CLASS A COMPLIANCEThis equipment has been tested and found to comply with the limits for a Class A digital device, pursu

Strany 63 - APPENDIX E - ABBREVIATIONS

ADC DSL Systems, Inc.14402 Franklin AvenueTustin, CA 92780-7013Tel: 714.832.9922Fax: 714.832.9924Technical AssistanceTel: 800.638.0031Tel: 714.730.322

Strany 64

152-388-100-02, Issue 2 List of FiguresH2TU-C-388 List 1 June 6, 2000 viiLIST OF FIGURES1. H2TU-C-388 List 1 Front Panel...

Strany 65 - CERTIFICATION AND WARRANTY

List of Tables 152-388-100-02, Issue 2viii June 6, 2000 H2TU-C-388 List 1LIST OF TABLES1. Front-Panel Description...

Strany 66 - ISO 9001/TL 9000

152-388-100-02, Issue 2 OverviewH2TU-C-388 List 1 June 6, 2000 1OVERVIEWThe HiGain® product family from ADC® is the industry’s first practical impl

Komentáře k této Příručce

Žádné komentáře