HiGain
HiGain
USER MANUAL
H2TU-R-402 List 4E Remote Unit
Part Number: 150-2450-45
CLEI: VARH1UUC
ALM
L
ESF
SF
LOOP
B8ZS
AMI
LBK
D
S
1
IN
BRG
OUT
RS-232
DCE
H
D
S
L
2
H
2
T
U
*
R
4
0
2
HiGain
4E
Zobrazit stránku 0
1 2 3 4 5 6 ... 45 46

Shrnutí obsahu

Strany 1 - USER MANUAL

HiGainHiGainUSER MANUALH2TU-R-402 List 4E Remote UnitPart Number: 150-2450-45CLEI: VARH1UUCALMLESFSFLOOPB8ZSAMILBKDS1INBRGOUTRS-232DCEHDSL2H2TU*R402Hi

Strany 2 - 152-402-145-02, Issue 2

Front Panel 152-402-145-02, Issue 24 June 16, 2000 H2TU-R-402Table 1. Front-Panel DescriptionFront-panel Feature FunctionList number Identifies th

Strany 3 - INSPECTING SHIPMENT

152-402-145-02, Issue 2 InstallationH2TU-R-402 June 16, 2000 5INSTALLATIONFigure 2. Installing the H2TU-R-402 List 4E1 Check the setting of the SCU

Strany 4 - TABLE OF CONTENTS

Installation 152-402-145-02, Issue 26 June 16, 2000 H2TU-R-402VERIFICATIONVerification without an Upstream DeviceVerify that the H2TU-R powers up.

Strany 5 - LIST OF TABLES

152-402-145-02, Issue 2 Viewing System ScreensH2TU-R-402 June 16, 2000 7VIEWING SYSTEM SCREENSThe H2TU-R-402 supports both local and remote logon t

Strany 6 - LIST OF FIGURES

Viewing System Screens 152-402-145-02, Issue 28 June 16, 2000 H2TU-R-402Figure 3. Logon ScreenTable 2. Logon Screen MenusPress this key: To acces

Strany 7 - OVERVIEW

152-402-145-02, Issue 2 Viewing System ScreensH2TU-R-402 June 16, 2000 9Table 3. Navigational Keys for the HiGain HDSL2 Maintenance Terminal Screen

Strany 8 - APPLICATIONS

Monitoring System Activity and Performance 152-402-145-02, Issue 210 June 16, 2000 H2TU-R-402MONITORING SYSTEM ACTIVITY AND PERFORMANCEThe HiGain

Strany 9 - FRONT PANEL

152-402-145-02, Issue 2 Monitoring System Activity and PerformanceH2TU-R-402 June 16, 2000 114 To initiate a loopdown of all active loopbacks, pres

Strany 10 - 4 June 16, 2000 H2TU-R-402

Monitoring System Activity and Performance 152-402-145-02, Issue 212 June 16, 2000 H2TU-R-402USING THE PERFORMANCE SCREENS TO VIEW PERFORMANCE DAT

Strany 11 - INSTALLATION

152-402-145-02, Issue 2 Monitoring System Activity and PerformanceH2TU-R-402 June 16, 2000 13Figure 6. H2TU-C DS1 31-day Performance HistoryFigure

Strany 12 - VERIFICATION

152-402-145-02, Issue 2ii June 16, 2000 H2TU-R-402Revision History of This ManualCopyrightJanuary 18, 2002© 2002 ADC DSL Systems, Inc. All rights

Strany 13 - VIEWING SYSTEM SCREENS

Monitoring System Activity and Performance 152-402-145-02, Issue 214 June 16, 2000 H2TU-R-402Figure 8. H2TU-C DS1 48-hour Performance HistoryFigur

Strany 14 - Table 2. Logon Screen Menus

152-402-145-02, Issue 2 Monitoring System Activity and PerformanceH2TU-R-402 June 16, 2000 15Figure 10. H2TU-C DS1 25-hour Performance HistoryFigur

Strany 15 - H2TU-R-402 June 16, 2000 9

Monitoring System Activity and Performance 152-402-145-02, Issue 216 June 16, 2000 H2TU-R-402Table 5. Error Acronyms Used on the DS1 Performance H

Strany 16 - PERFORMANCE

152-402-145-02, Issue 2 Monitoring System Activity and PerformanceH2TU-R-402 June 16, 2000 17Performance History at the HDSL2 InterfaceFigure 12 is

Strany 17 - SPACEBAR ENTER

Monitoring System Activity and Performance 152-402-145-02, Issue 218 June 16, 2000 H2TU-R-402Figure 14. H2TU-R HDSL2 25-hour Performance HistoryFi

Strany 18 - 12 June 16, 2000 H2TU-R-402

152-402-145-02, Issue 2 Monitoring System Activity and PerformanceH2TU-R-402 June 16, 2000 19USING THE PERFORMANCE SCREENS TO VIEW ALARM DATATo acc

Strany 19 - H2TU-R-402 June 16, 2000 13

Monitoring System Activity and Performance 152-402-145-02, Issue 220 June 16, 2000 H2TU-R-402Figure 17. H2TU-C DS1 Alarm History ScreenTable 7. H2

Strany 20 - 14 June 16, 2000 H2TU-R-402

152-402-145-02, Issue 2 Monitoring System Activity and PerformanceH2TU-R-402 June 16, 2000 21Alarm History at the HDSL2 InterfaceFigure 18 and Figu

Strany 21 - H2TU-R-402 June 16, 2000 15

Monitoring System Activity and Performance 152-402-145-02, Issue 222 June 16, 2000 H2TU-R-402USING THE EVENT LOG TO TRACK SYSTEM EVENTSTo view a r

Strany 22

152-402-145-02, Issue 2 Monitoring System Activity and PerformanceH2TU-R-402 June 16, 2000 23Table 9. Event Log MessagesEvent Log MessagesDS1 Alarm

Strany 23 - H2TU-R-402 June 16, 2000 17

152-402-145-02, Issue 2 Using This ManualH2TU-R-402 June 16, 2000 iiiUSING THIS MANUALThe following conventions are used in this manual:• Monospace

Strany 24 - 18 June 16, 2000 H2TU-R-402

Loopback Operation 152-402-145-02, Issue 224 June 16, 2000 H2TU-R-402LOOPBACK OPERATIONHiGain HDSL2 has a family of loopback options for analyzing

Strany 25 - H2TU-R-402 June 16, 2000 19

152-402-145-02, Issue 2 Loopback OperationH2TU-R-402 June 16, 2000 25Table 10. Summary of HiGain HDSL2 Loopback Codes and Activation MethodsMethod

Strany 26 - 20 June 16, 2000 H2TU-R-402

Loopback Operation 152-402-145-02, Issue 226 June 16, 2000 H2TU-R-402Special Loopback CommandsIn addition to the GNLB loopback command mode, a HiG

Strany 27 - H2TU-R-402 June 16, 2000 21

152-402-145-02, Issue 2 Loopback OperationH2TU-R-402 June 16, 2000 275 Repeat Step 2. If the test passes, the problem is in the downstream directio

Strany 28 - 22 June 16, 2000 H2TU-R-402

Loopback Operation 152-402-145-02, Issue 228 June 16, 2000 H2TU-R-402A2LB Test ProceduresUsing the codes listed in Table 11, a network tester can

Strany 29 - Table 9. Event Log Messages

152-402-145-02, Issue 2 Loopback OperationH2TU-R-402 June 16, 2000 294 Once armed, the H2TU-R-402 can be looped back by sending Intelligent Office

Strany 30 - LOOPBACK OPERATION

Loopback Operation 152-402-145-02, Issue 230 June 16, 2000 H2TU-R-402A3LB and A4LB Test ProceduresThe H2TU-C can be looped back by sending the Add

Strany 31 - H2TU-R-402 June 16, 2000 25

152-402-145-02, Issue 2 Appendix A - SpecificationsH2TU-R-402 June 16, 2000 31APPENDIX A - SPECIFICATIONSPowerHDSL2 Span Voltage -180 VdcLine or Lo

Strany 32 - LOOPBACK TEST PROCEDURES

Appendix A - Specifications 152-402-145-02, Issue 232 June 16, 2000 H2TU-R-402LOOP ATTENUATIONEach loop has no more than 35 dB of loss at 196 kHz,

Strany 33 - Figure 22. Loopback Modes

152-402-145-02, Issue 2 Appendix A - SpecificationsH2TU-R-402 June 16, 2000 33CRAFT PORTFigure 24 shows the pinout for the craft port connector and

Strany 34 - A2LB Test Procedures

Table of Contents 152-402-145-02, Issue 2iv June 16, 2000 H2TU-R-402TABLE OF CONTENTSOverview ____________________________________________________

Strany 35 - H2TU-R-402 June 16, 2000 29

Appendix B - Functional Operation 152-402-145-02, Issue 234 June 16, 2000 H2TU-R-402APPENDIX B - FUNCTIONAL OPERATIONADC HDSL2 technology provides

Strany 36 - A3LB and A4LB Test Procedures

152-402-145-02, Issue 2 Appendix C - CompatibilityH2TU-R-402 June 16, 2000 35APPENDIX C - COMPATIBILITYThe HiGain HDSL2 system uses HDSL2 transmiss

Strany 37 - APPENDIX A - SPECIFICATIONS

Appendix D - Product Support 152-402-145-02, Issue 236 June 16, 2000 H2TU-R-402APPENDIX D - PRODUCT SUPPORTADC Customer Service Group provides exp

Strany 38 - IST 4E CARD CONNECTOR

Appendix E - Abbreviations 152-402-145-02, Issue 237 June 16, 2000 H2TU-R-402APPENDIX E - ABBREVIATIONSAACO: Alarm Cutoff ACON: Auto Conversion

Strany 39 - RAFT PORT

152-402-145-02, Issue 2 Appendix E - AbbreviationsH2TU-R-402 June 16, 2000 38NREM: Network Remote Loopback NTF: No Trouble Found OOOF: Out-of-Fr

Strany 40 - 34 June 16, 2000 H2TU-R-402

CERTIFICATION AND WARRANTYFCC CLASS A COMPLIANCEThis equipment has been tested and found to comply with the limits for a Class A digital device, pursu

Strany 41 - APPENDIX C - COMPATIBILITY

ADC DSL Systems, Inc.14402 Franklin AvenueTustin, CA 92780-7013Tel: 714.832.9922Fax: 714.832.9924Technical AssistanceTel: 800.638.0031Tel: 714.730.322

Strany 42 - APPENDIX D - PRODUCT SUPPORT

152-402-145-02, Issue 2 List of TablesH2TU-R-402 June 16, 2000 vLIST OF TABLES1. Front-Panel Description...

Strany 43 - APPENDIX E - ABBREVIATIONS

List of Figures 152-402-145-02, Issue 2vi June 16, 2000 H2TU-R-402LIST OF FIGURES1. H2TU-R-402 List 4E Front Panel...

Strany 44 - H2TU-R-402 June 16, 2000 38

152-402-145-02, Issue 2 OverviewH2TU-R-402 June 16, 2000 1OVERVIEWThe HiGain® HDSL2 product family from ADC® is the industry’s first practical impl

Strany 45 - CERTIFICATION AND WARRANTY

Overview 152-402-145-02, Issue 22 June 16, 2000 H2TU-R-402COMPATIBILITYThe H2TU-R-402 is designed to mount in any 400 or 200 mechanics shelf. For

Strany 46 - ISO 9001/TL 9000

152-402-145-02, Issue 2 Front PanelH2TU-R-402 June 16, 2000 3FRONT PANELFigure 1 shows the H2TU-R-402 List 4E front panel. Table 1 on page 4 descri