Assignment of the binary outputs and inputs as required,
see 3.07 Fct. “HARDWARE” and Sect. 3.2 “Factory settings”.
Current output I – active or passive mode
– internal power source for the binary outputs and inputs
Binary outputs/inputs terminal B1: Terminals
pulse output B1
status output B1 or
control input B1
terminal B2:
status output B2 or
control input B2
2.1 Combinations of outputs and inputs
2 Electrical connection of outputs and inputs
B1 B
B2 I+ I I
Binary outputs
and inputs
Current output
Output/input combinations 1) – 6)
T
erminals: I+ / I / I
B1 / B
B2 / B
Combination: 1) IPS
2) IPC
3) ICS
4) ISC
5) IS1S2
6) IC1C2
I = current output
P = pulse output
S = status output
C = control input
2.2 Current output I
The current output is galvanically isolated from all input and output circuits.
Setting data and functions can note down on page 0/3.
Please also refer to Sect. 3.2 “Factory settings”.
Typical current output
All operating data and functions can be set.
Display version: IFC 090 D, see Sect. 4 and 5.6, Fct. 1.05 for operator control
Basic version: IFC 090 B, see Sect. 6.2 for operator control
The current output can also be used as an internal voltage source for the binary
outputs and inputs.
U
int
= 15 V DC I = 23 mA when operated without receiver instruments at the current output
I = 3 mA when operated with receiver instruments at the current output
Connection diagrams,
see Sect. 2.6: diagrams 1 2 3 6 9 10 11
I+ approx. 15 V DC positive
voltage of current output
I current sink
I chassis ground,
current output