ADC Cuda 12000 Technické informace Strana 581

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 652
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 580
Cuda 12000 IP Access Switch CLI Reference Guide
snmp-server view 577
Example 1
In this example, the user allows access to the entire MIB:
cli:192.168.208.3:root# snmp-server view auditorview1 1.3.6.1 included
cli:192.168.208.3:root# show snmp view
row count: 5
View Name Subtree Type Storage Status
---------------- --------------------------- -------- ----------- -----------
public 1.3.6.1 Included NonVolatile Active
private 1.3.6.1 Included NonVolatile Active
guitraps 1.3.6.1 Included NonVolatile Active
v1default 1.3.6.1 Included NonVolatile Active
auditorview1 1.3.6.1 Included NonVolatile Active
Example 2
In this example, the user excludes sensitive SNMP configuration information:
cli:192.168.208.3:root# snmp-server view auditorview2 snmpModules excluded
cli:192.168.208.3:root# show snmp view
row count: 5
View Name Subtree Type Storage Status
---------------- --------------------------- -------- ----------- -----------
public 1.3.6.1 Included NonVolatile Active
private 1.3.6.1 Included NonVolatile Active
guitraps 1.3.6.1 Included ReadOnly Active
v1default 1.3.6.1 Included NonVolatile Active
auditorview2 1.3.6.1.6.3 Excluded NonVolatile Active
Zobrazit stránku 580
1 2 ... 576 577 578 579 580 581 582 583 584 585 586 ... 651 652

Komentáře k této Příručce

Žádné komentáře